MODELS |
FEATURES |
NOMINAL
OPENING |
MOVEMENT
RANGE |
MOVEMENT
TYPE |
CODES/LOADING
TRAFFIC TYPE |
APPLICATIONS |
 |
LMS
LSS |
- High performance monolithic waterproof expansion
joint sealing system.
- Membrane seal with perforated wings bonded to deck
with impact absorbing elastomeric concrete.
- Hard, elastic, abrasion resistant embed material
that flexes with deck loads.
- Model LSS available for openings up to 12"
|
2"-4.5"
51 - 114 |
.75"-6.5"
19 - 165 |
 |
ADA
Pedestrian Vertical |
- Parking Deck Drive Lanes
- Traffic Speed < 15mph
- Turning Lanes
- Helix @ Turns
- Concourse Areas
- Pedestrian Bridges
- High Volume Pedestrian Traffic
|
 |
EBS |
- No blockouts required - waterproof sealing system
becomes integral with concrete deck.
- Tenacious epoxy anchoring system bonds seal to concrete,
aluminum and steel.
- Engineered to withstand heavy traffic loads and
extreme weather conditions.
- Available with a 5-year warranty
|
1"-4"
25 - 102 |
.75"-5.5"
19 - 140 |
 |
ADA
Pedestrian Vehicular Highway
Delivery Snowplows |
- Parking Deck Drive Lanes
- Traffic Speed > 15mph
- Enplane/Deplane Road & Bridge
- Auto Entrance Ramps o Helix @ Turns & Brake-overs
- Heavy Loads/Snowplows & Buses
- Below Grade Areas & Retaining Walls
|
 |
ASB
ABC |
- Heavy-duty aluminum frame with protective interlocking metal retaining angle.
- Replaceable locking Elastoprene seal with secondary fabric reinforced rubber gutter.
- Structural aluminum frame bonded to dock with impact absorbing elastomeric concrete.
- Hard, elastic, abrasion resistant embed material that flexes with deck loads.
|
2"- 4.5"
51 - 114 |
.75"- 6.5"
19 - 165 |
|
ADA
Pedestrian
Vehicular
Delivery |
- Parking Deck Drive Lanes
- Traffic Speed < 15mph
- Turning Lanes
- Helix @ Turns
- Concourse Areas
- Pedestrian Bridges
- High Volume Pedestrian Traffic
|
 |
SSM
SSC
SCG |
- Continuous locking ElastopreneŽ seal ties directly
into deck waterproofing.
- Heavy-duty aluminum frame with protective interlocking
metal retaining cap.
- Leg height adjusts to accommodate pavers, split-slabs
and other topping surfaces.
- Available with a 5-year warranty.
|
2"-4.5"
51 - 114 |
.75"-6.5"
19 - 165 |
 |
ADA
Pedestrian
Vehicular |
- Split Slab Waterproof Conditions
- Plaza Decks Paver Areas
- Traffic Speed < 15mph
- High Volume Pedestrian Traffic
- Longitudinal Joints
|
 |
EMS |
- Metal reinforced rubber panels lock down continuous
wing of ElastopreneŽ membrane seal.
- Non-Slip surface for severe applications and extreme
weather conditions.
- Specialty bedding compound insures a watertight
seal to the concrete deck.
- Seal profiles are ADA compliant.
|
2"-4.5"
51 - 114 |
.75"-6.5"
19 - 165 |
 |
ADA
Pedestrian Vehicular
Highway
Delivery
Snowplows |
- Parking Deck Drive Lanes
- Top Deck/Snowplow Areas
- Heavy Loads/Buses & Delivery Vehicles
- Traffic Speed > 15mph
- Helix & Turning Lanes
- Enplane/Deplane Ramps Road & Bridge
- Fork Trucks / Loading Docks
|
 |
EMC
|
- Cast-in design eliminates drilling anchor holes in post-tension concrete decks.
- Metal reinforced rubber panels lock down continuous wing of ElastopreneŽ membrane seal.
- Non-Slip surface for severe applications and extreme weather conditions.
- Seal profiles are ADA compliant.
|
2"-4.5"
51 - 114 |
.75"-6.5"
19 - 165 |
 |
ADA
Pedestrian Vehicular
Highway
Delivery
Snowplows |
- Post tensioned concrete decks
- Parking Deck Drive Lanes
- Top Deck/Snowplow Areas
- Heavy Loads/Buses & Delivery Vehicles
- Traffic Speed > 15mph
- Helix & Turning Lanes
- Enplane/Deplane Ramps Road & Bridge
- Fork Trucks / Loading Docks
|
 |
CIS
BIS |
- Cast-In design eliminates slab-to-slab vertical
offsets and need for blockouts.
- High strength hook bolts adjust around post tension
cables.
- Seismic centering device with dynamic load impact
dampener and molded nylon ends.
- Replaceable reinforced rubber waterproofing gutter.
|
4"-10"
102 - 254 |
2.5"-12.5"
64 - 318 |
 |
ADA
Pedestrian
Vehicular
Delivery |
- Post Tension Concrete Decks
- Parking Deck Drive Lanes
- Turning Lanes & Entrance Ramps
- Traffic Speed < 30mph
- High Volume Pedestrian Traffic
- Longitudinal Joints
|
 |
SMS |
- Surface mount design eliminates need for blockouts.
- Load rated heavy-duty metal slide plate with impact
and sound dampener.
- Aluminum base member incorporates tire impact deflection
design and integral rubber gutter.
- Seismic centering device with dynamic load impact
dampener and molded nylon ends.
|
4"-10"
102 - 254 |
2"-12.5"
51 - 318 |
 |
ADA
Pedestrian
Vehicular |
- Parking Deck Drive Lanes
- Traffic Speed < 15mph
- Turning Lanes & Entrance Ramps
- Heavy Loads
|
 |
SSP
STS
SSS
|
- Load rated heavy-duty metal slide plate with impact
and sound dampener.
- Recessed extension plates allow smooth slab-to-slab
transition.
- Seismic centering device with dynamic load impact
dampener and molded nylon ends.
- Interlocking frame design insures proper alignment.
|
4"-10"
102 - 254 |
1"-12.5"
25 - 318 |
 |
ADA
Pedestrian
Vehicular |
- Parking Deck Drive Lanes
- Traffic Speed < 30mph
- Turning Lanes & Entrance Ramps
- Heavy Loads
- Longitudinal Joints
- Pedestrian Bridges
|
 |
SPV
|
- Custom engineered for wide sesimic vehicular applications.
- Telescoping design allow smooth deck-to-deck transition.
- Designed for seismic and base isolated X,Y & Z rotational movement.
- Professional engineering calculations provided.
|
24"(610mm)
and above |
Engineered to Order
|
|
ADA
Pedestrian
Vehicular |
- Parking Deck drive Lanes
- Traffic Speed < 15mph
- Base Isolated Structures
- Stadiums & Arenas
- Building-to-Parking Structure areas
- Hospitals
|
 |
SNB
|
- No-Bump slide plate design is load rated heavy duty.
- Recessed extension plates allow smooth interior floor-to-floor transition.
- Seismic Centering device with dynamic load impact dampener and metal ball ends Interlocking frame design insures proper alignment.
|
2"(51mm)-10" 254mm)
|
Seismic 1"(25mm)-15"(381mm)
Thermal - Engineered to Order |
|
ADA
Pedestrian
Heavy Equipment |
- Interior - heavy loads
- No-bump sensitive equipment
- Warehouse
- Loading Docks
- Postal Facilities
- Interior Service Areas
|
 |
GID
AID |
- Load rated heavy-duty steel or aluminum slide plate.
- Crowned cover design accommodates vertical offsets in concrete decks.
- EPDM rubber base pads absorb vehicular impact loads.
- Fabric reinforced rubber waterproofing gutter with optional drain tube assembly.
|
1"- 15"
25 - 381
|
2"- 10"
51 - 254
|
 |
ADA
Pedestrian
Vehicular |
Parking Deck Drive Lanes
- Heavy Loads
- Traffic Speed < 15mph
- Pedestrian Bridges
- Concourse Areas
- Sidewalk Areas
|
 |
HSC |
- Load rated heavy-duty aluminum slide plate with
impact and sound dampener.
- Hinge design accommodates vertical offsets in concrete
decks.
- Integral fabric reinforced rubber waterproofing
gutter.
- ADA compliant non-slip raised pattern design.
|
HSC
2.5"- 5"
64 - 127
HSC
Engineered to Order
|
1"- 9"
25 - 229
|

|
ADA
Pedestrian
Vehicular |
- Areas with Vertical Slab Offsets
- High Volume Pedestrian Traffic
- Pedestrian Bridges
- Traffic Speed < 15mph
- Concourse Areas
- Sidewalk Areas
|
 |
RSC |
- Covers expansion joint recess and vertical offsets in concrete slab.
- Convex shaped aluminum cover with raised slip resistant pattern.
- ADA compliant rubber nosing pads with mechanical hinges.
|
1"- 5"
25 - 127
|
0"- 7.5"
0 - 191
Vehicular
0"- 8.5"
0 - 216
Pedestrian
|
|
ADA
Pedestrian
Vehicular |
- Stadium Seating Bowl
- Low Speed Vehicular Traffic
- Areas with Vertical Slab Offsets
- High Volume Pedestrian Areas
- Pedestrian Bridges
- Traffic Speed < 15mph
- Concourse Areas
- Sidewalk Areas
|
 |
ESS |
- Preformed silicone strip bonded to a rectangular polyurethane backer creates a binary sealing system
- System conforms to irregular openings and is soundproof, dust-proof, water, and air tight
- Engineered 1/2" thick preformed silicone strip virtually eliminates possibility of punctures
- Resistant to UV, ozone, and extreme temperatures
|
.9" - 3.25"
22 - 83
|
.5" - 7.5"
13 - 191
|
 |
Vertical
Horizontal
Requires
Cover
|
- Color Matching of Wall Finishes
- Vertical Brick & Block Walls
- Vertical Precast & Perimeter Walls
- Abutments
- Stair Tower & Slab-To-Wall Conditions
- Vertical Joints with No Blockouts
- Irregular Expansion Joint Openings
|
 |
SIF |
- Binary silicone seal and impregnated foam nearly eliminates possibility of punctures.
- Permanently elastic and will expand to the required joint movement.
- Watertight, dust-proof, airtight, soundproof seal resilient and flexible to -39°F.
- Seismic movement capability with near zero tensile stress at bond line.
|
.5"- 8"
13 - 203
|
.25"- 12"
6 - 305
|
|
Vertical
Horizontal
Requires
Cover |
- Color Matching of Wall Finishes
- Vertical Brick & Block Walls
- Vertical Precast & Perimeter Walls
- Abutments
- Stair Tower & Slab-To-Wall Conditions
- Vertical Joints with No Blockouts
- Irregular Expansion Joint Openings
|
 |
EIF |
- Epoxy bonded impregnated foam block provides additional point load support.
- Conforms to irregular openings virtually eliminating the risk of costly water damage.
- System generates constant internal pressure providing a permanent weather-tight seal.
- Permanently elastic and will expand and accommodate the concrete deck movement.
|
.5"- 4.0"
13 - 102
|
.25"- 6.0"
6 - 152
|
|
Vertical
Horizontal |
- Expands to Fill Irregular Openings
- Roadway & Pedestrian Bridges
- Pre-cast Concrete Tilt-Up Walls
- Below Grade Waterproofing
- Seating Bowl Areas (Treads & Risers)
- Stair Tower & Slab-to-Wall Conditions
- Joint Openings with No Blockouts
|
 |
ERS |
- Waterproof sealing system not requiring blockouts.
- Closed cell expanded ElastopreneŽ rubber seal.
- Tenacious thixotropic epoxy anchoring system bonds
to concrete, aluminum and steel.
- Designed for varying and irregular expansion joint
openings.
|
.9"-3.25"
22 - 83 |
.5"-5"
13 - 127 |
 |
Vertical
Horizontal
Requires Cover |
- Irregular Expansion Joint Openings
- Seating Bowl Areas (Treads & Risers)
- Vertical Brick & Block Walls
- Vertical Precast & Perimeter Walls
- Stair Tower & Slab-to-Wall Conditions
- Joint Openings with No Blockouts
|
 |
VSS |
- Seismic seal snap-locked into two aluminum frames.
- No visible aluminum or hardware.
- Visual seals are available in standard and custom
colors.
- Resistant to UV, ozone, acid rain, most chemicals
and extreme temperatures.
|
2"-10"
51 - 254 |
1"-15"
25 - 381 |
 |
Vertical |
- Seismic Vertical Joint Openings
- Vertical Precast & Perimeter Walls
- Vertical Openings with No Blockouts
- Color Matching of Wall Finishes
- Available with Secondary Water Seal
|
 |
ECS
VCS |
- Colored rubber multi-web seal profile accommodates
expansion and compression.
- No mechanical anchors or metal components.
- Seal profiles are ADA compliant and provide a smooth transition for pedestrian traffic areas.
- Model ECS is for horizontal applications
- Model VCS is for vertical applications
|
1.3"-3.8"
33 - 97 |
.9"-5.5"
23 - 140 |
 |
Horizontal
Vertical |
- Vertical Precast & Perimeter Walls
- Color Matching of Wall Finishes
- Sidewalk Areas
- Parking Deck Drive Lanes
- Concourse Areas
- Pedestrian Bridges
|
 |
PPT |
- Factory molded seal provides flush ADA compliant surface.
- Zero recess design eliminates collection of dirt.
- Uniform thickness and flush surface.
- Can be easily repaired.
- For small movement applications.
|
.75"- 1.0"
19 - 25
|
.5"- 4.25"
13 - 108
|
 |
Horizontal
Vertical |
- Seating Bowl Area (Treads & Risers)
- Small Movement Joints
- Building Interiors
|
 |
FGS |
- Flexible gutter collects and moves water away from
the expansion joint system.
- Rubber gutter is fabric reinforced to minimize
material elongation.
- Cost-effective solution for remedial repair of
leaking expansion joint systems.
- Installed in blockouts or underslab conditions.
|
3"-21"
76 - 533 |
1"-41"
25 - 1041 |
 |
N/A |
- Primary Water Control
- Secondary Water Containment
- Cost Effective Waterproofing
- Areas Over Occupied Space
|
 |
PF |
- ASTM Test Standards E-119, E-1399 and E-1966.
- Additional Standards: UL 263, UL 2079, UBC 43-1,
UBC 7-1, ANSI A2.1 and NFPA 251.
- Available in 2, 3, 4 and 5 hour ratings and cycle
tested for Class II & III movement including lateral
shear.
- Listed with UL, Intertek (Omega Point Laboratories), California
State Fire Marshal and ICBO Evaluation Service.
|
1"-32"
51 - 813 |
0"-48"
25 - 1219 |
 |
Ratings:
1 Hour
2 Hour
3 Hour
4 Hour
5 Hour |
- Horizontal Concrete Joint Openings
- Vertical Concrete Joint Openings
- Horizontal Gypboard Joint Openings
- Vertical Gypboard Joint Openings
|